Skip to main content
Advanced Search
Search Terms
Content Type

Exact Matches
Tag Searches
Date Options
Updated after
Updated before
Created after
Created before

Search Results

43 total results found

Locating

Locating Equipment

8100

Contract Specific Procedures

contract
process
procedures

VEHICLES

811 Ticket system

Procedures for 811 tickets

process
Delay
Ticket
811
weather
time
input

Locator Info

Utility Hookup Guides

Printable Utility Hookup guides

Fleet Contacts

IT Archive

RD8200

Locating Equipment

8100
RD8100

RD7200

Locating Equipment

Geophysical Survey Systems, Inc. GPR

Locating Equipment

Ground Penetrating Radar

GPR
Utility Scan
untilityscan

MAINTENANCE

VEHICLES

Active Frequencies

Locating Equipment

Active frequencies are applied to a buried conductor using the transmitter. The transmitter can apply a signal using these methods:​

Printable Guides

Utility Hookup Guides

All Territories

Fleet Contacts

Accident Reporting

VEHICLES

RD8200 Manual

Locating Equipment RD8200

https://support.radiodetection.com/hc/en-gb/articles/360052707931-RD8200-Locator-overview

8100
manual
RD 8100
RD8100

RD7200 Manual

Locating Equipment RD7200

https://support.radiodetection.com/hc/en-gb/articles/360052074812-RD7200-System-Overview

manual
RD 7200
RD7200
7200

Utility Scan Manual

Locating Equipment Geophysical Survey Systems, Inc. GPR

Utility Scan Quick Start Guide

manual
utilityscan
GPR
Utility Scan

Lakeland

Contract Specific Procedures

Lakeland Fiber Locating ProceduresNever skin or cut a locate wire.If this is done, immediately tape it up and call Neil Cleveland at Lakeland - 813.957.3965Breakpoint will be back charged for repairs, and those repairs may be passed on to the locator. Do not s...

process
procedures
procedure
lakeland fiber
fiber
lakeland

OUC

Contract Specific Procedures

blah blah blah

What is Ground Penetrating Radar?

Locating Equipment Geophysical Survey Systems, Inc. GPR

Ground Penetrating Radar (GPR), also called georadar or ground probing radar. GPR uses three main components: a control unit, an antenna, and a power supply. GSSI GPR systems can operate on various power sources, including small rechargeable batteries, vehicle...

RD8200 Hardware Layout

Locating Equipment RD8200

Keypad​LCD with auto backlight​Haptic (vibration) feedback​Speaker​Battery compartment​Accessory connector​Headphone connector​Bluetooth module antenna​SWING Warning system​Optional Lithium-Ion battery pack​USB connector (inside the battery compartment)Power k...

RD7200 Hardware Layout

Locating Equipment RD7200

Keypad​LCD with auto backlight​Haptic (vibration) feedback​Speaker​Battery compartment​Accessory connector​Headphone connector​Bluetooth module antenna​SWING Warning system​Optional Lithium-Ion battery pack​USB connector (inside the battery compartment)Power k...

OIL CHANGE

VEHICLES MAINTENANCE

ProcedureWhen it’s dueIf the dash indicator comes on or your mileage/sticker says it’s due, it’s time.What you doNotify the Fleet Manager immediately that your vehicle is due for service.Fleet Manager: 813-892-4069Wait for instructions on when and where to go....

TIRES

VEHICLES MAINTENANCE

APPEARANCE

VEHICLES MAINTENANCE

Delaying tickets

811 Ticket system

Induction Clamp

Locating Equipment Active Frequencies

An optional signal clamp can be connected to the transmitter and clamped around a cable or pipe to apply the transmitter signal. This method of applying the transmitter signal is particularly useful on insulated live wires and removes the need to disconnect th...

Direct Connection

Locating Equipment Active Frequencies

In Direct Connection, you connect the transmitter output directly to the utility. The transmitter will then apply a discrete signal which you can locate using the locator. This is the preferred method of applying a transmitter signal to a utility and in the ma...

Choice of Frequency

Locating Equipment Active Frequencies

512 kHz​This low frequency is most useful for line tracing and identification over long distances. It does not couple easily to unwanted lines.​                                     but​ It is too low for induction, and it falls within the band of power freque...

RD7200 Utility Hookup Quick Card

Utility Hookup Guides Printable Guides

Water:Metallic: Direct connect to valve/hydrantPlastic (PVC) w/ tracer wire: Red to tracer wire Black to ground stake No tracer wire: Use sondeFreq: 8 kHz–33 kHzSewer:Non-metallic: Use sonde in cleanout/cameraMetallic (rare): Direct connectFreq: 33 kHz or 512 ...

Locator Reference Guide Checklist

Utility Hookup Guides Printable Guides

Utility Locating Quick Reference Guide 1. Arrival & Safety Check in & review site maps Wear PPE (vest, hard hat, gloves, boots, glasses) Walk job site & identify hazards Plan which utilities need locating 2. Equipment Setup Inspect & power on RD7200/RD8200 Run...

OUC Update Files and Data

IT Archive

GIS Contact info - Dawn Harris - GIS Supervisor - DHarris@ouc.comMichael Weiner - GIS Programmer - MWeiner@ouc.comOUC updates are provided via an FTP connection. Using an FTP client (CoreFTP is preferred by OUC), below is an example of the connection profile. ...

Brevard Update Process

IT Archive

GIS Contact info - Newman, Rae <Rae.Newman@brevardfl.gov>The Brevard updates will be sent to you via email. Request them from Rae Newman. Once you have downloaded the Brevard GIS data, download the attached "Import to PostGIS.zip" file, and then unzip it. Unzi...

Lake Worth Update Process

IT Archive

GIS Contact info - Newman, Rae <Rae.Newman@brevardfl.gov>The Brevard updates will be sent to you via email. Request them from Rae Newman. Once you have downloaded the Brevard GIS data, download the attached "Import to PostGIS.zip" file, and then unzip it. Unzi...