RD7200 Utility Hookup Quick Card
- Water:
- Metallic: Direct connect to valve/hydrant
- Plastic (PVC) w/ tracer wire: Red to tracer wire
- Black to ground stake
- No tracer wire: Use sonde
- Freq: 8 kHz–33 kHz
- Sewer:
- Non-metallic: Use sonde in cleanout/camera
- Metallic (rare): Direct connect
- Freq: 33 kHz or 512 Hz sonde
- Electric:
- Clamp on insulated live cable
- Alt: Direct connect to sheath/ground (if safe)
- Check passive power first
- Freq: 8–33 kHz
- Gas:
- Plastic w/ tracer wire: Red to tracer wire
- Steel main: Direct connect to valve/riser
- Freq: 512 Hz–8 kHz
- Fiber Optic:
- Armored: Clamp around sheath
- With tracer wire: Direct connect
- Freq: 512 Hz–8 kHz
- Chilled Water:
- Usually metallic: Direct connect to valve/pipe Clamp if insulated
- Freq: 8 Hz–8 k
- Reclaimed Water:
- Plastic w/ tracer wire: Direct connect
- No tracer wire: Induction
- Freq: Start low, increase if needed
- Best Practices:
- Direct connect if possible
- Ground stake 10–20 ft away, perpendicular
- Start low frequency
- Confirm with multiple sweeps & modes