Skip to main content

RD7200 Utility Hookup Quick Card

  • Water:
    • Metallic: Direct connect to valve/hydrant
    • Plastic (PVC) w/ tracer wire: Red to tracer wire
    • Black to ground stake
    • No tracer wire: Use sonde
    • Freq: 8 kHz–33 kHz
  • Sewer:
    • Non-metallic: Use sonde in cleanout/camera
    • Metallic (rare): Direct connect
    • Freq: 33 kHz or 512 Hz sonde
  • Electric:
    • Clamp on insulated live cable
    • Alt: Direct connect to sheath/ground (if safe)
    • Check passive power first
    • Freq: 8–33 kHz
  • Gas:
    • Plastic w/ tracer wire: Red to tracer wire
    • Steel main: Direct connect to valve/riser
    • Freq: 512 Hz–8 kHz
  • Fiber Optic:
    • Armored: Clamp around sheath
    • With tracer wire: Direct connect
    • Freq: 512 Hz–8 kHz
  • Chilled Water:
    • Usually metallic: Direct connect to valve/pipe Clamp if insulated
    • Freq: 8 Hz–8 k
  • Reclaimed Water:
    • Plastic w/ tracer wire: Direct connect
    • No tracer wire: Induction
    • Freq: Start low, increase if needed
  • Best Practices:
    • Direct connect if possible
    • Ground stake 10–20 ft away, perpendicular
    • Start low frequency
    • Confirm with multiple sweeps & modes